Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Biomater ; 180: 154-170, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38621600

RESUMO

Bacterial infection remains a significant problem associated with orthopaedic surgeries leading to surgical site infection (SSI). This unmet medical need can become an even greater complication when surgery is due to malignant bone tumor. In the present study, we evaluated in vitro titanium (Ti) implants subjected to gallium (Ga) and silver (Ag)-doped thermochemical treatment as strategy to prevent SSI and improve osteointegration in bone defects caused by diseases such as osteoporosis, bone tumor, or bone metastasis. Firstly, as Ga has been reported to be an osteoinductive and anti-resorptive agent, its performance in the mixture was proved by studying human mesenchymal stem cells (hMSC) and pre-osteoclasts (RAW264.7) behaviour. Then, the antibacterial potential provided by Ag was assessed by resembling "The Race for the Surface" between hMSC and Pseudomonas aeruginosa in two co-culture methods. Moreover, the presence of quorum sensing molecules in the co-culture was evaluated. The results highlighted the suitability of the mixture to induce osteodifferentiation and reduce osteoclastogenesis in vitro. Furthermore, the GaAg surface promoted strong survival rate and retained osteoinduction potential of hMSCs even after bacterial inoculation. Therefore, GaAg-modified titanium may be an ideal candidate to repair bone defects caused by excessive bone resorption, in addition to preventing SSI. STATEMENT OF SIGNIFICANCE: This article provides important insights into titanium for fractures caused by osteoporosis or bone metastases with high incidence in surgical site infection (SSI) because in this situation bacterial infection can become a major disaster. In order to solve this unmet medical need, we propose a titanium implant modified with gallium and silver to improve osteointegration, reduce bone resorption and avoid bacterial infection. For that aim, we study osteoblast and osteoclast behavior with the main novelty focused on the antibacterial evaluation. In this work, we recreate "the race for the surface" in long-term experiments and study bacterial virulence factors (quorum sensing). Therefore, we believe that our article could be of great interest, providing a great impact on future orthopedic applications.


Assuntos
Técnicas de Cocultura , Gálio , Células-Tronco Mesenquimais , Osteogênese , Pseudomonas aeruginosa , Prata , Titânio , Titânio/química , Titânio/farmacologia , Prata/farmacologia , Prata/química , Humanos , Gálio/farmacologia , Gálio/química , Camundongos , Células-Tronco Mesenquimais/efeitos dos fármacos , Animais , Osteogênese/efeitos dos fármacos , Pseudomonas aeruginosa/efeitos dos fármacos , Reabsorção Óssea/patologia , Propriedades de Superfície , Células RAW 264.7 , Antibacterianos/farmacologia , Antibacterianos/química , Infecções Bacterianas/prevenção & controle
2.
Front Bioeng Biotechnol ; 11: 1303313, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38144539

RESUMO

Excessive bone resorption is one of the main causes of bone homeostasis alterations, resulting in an imbalance in the natural remodeling cycle. This imbalance can cause diseases such as osteoporosis, or it can be exacerbated in bone cancer processes. In such cases, there is an increased risk of fractures requiring a prosthesis. In the present study, a titanium implant subjected to gallium (Ga)-doped thermochemical treatment was evaluated as a strategy to reduce bone resorption and improve osteodifferentiation. The suitability of the material to reduce bone resorption was proven by inducing macrophages (RAW 264.7) to differentiate to osteoclasts on Ga-containing surfaces. In addition, the behavior of human mesenchymal stem cells (hMSCs) was studied in terms of cell adhesion, morphology, proliferation, and differentiation. The results proved that the Ga-containing calcium titanate layer is capable of inhibiting osteoclastogenesis, hypothetically by inducing ferroptosis. Furthermore, Ga-containing surfaces promote the differentiation of hMSCs into osteoblasts. Therefore, Ga-containing calcium titanate may be a promising strategy for patients with fractures resulting from an excessive bone resorption disease.

3.
Int J Mol Sci ; 24(10)2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-37240108

RESUMO

Previously, functional coatings on 3D-printed titanium implants were developed to improve their biointegration by separately incorporating Ga and Ag on the biomaterial surface. Now, a thermochemical treatment modification is proposed to study the effect of their simultaneous incorporation. Different concentrations of AgNO3 and Ga(NO3)3 are evaluated, and the obtained surfaces are completely characterized. Ion release, cytotoxicity, and bioactivity studies complement the characterization. The provided antibacterial effect of the surfaces is analyzed, and cell response is assessed by the study of SaOS-2 cell adhesion, proliferation, and differentiation. The Ti surface doping is confirmed by the formation of Ga-containing Ca titanates and nanoparticles of metallic Ag within the titanate coating. The surfaces generated with all combinations of AgNO3 and Ga(NO3)3 concentrations show bioactivity. The bacterial assay confirms a strong bactericidal impact achieved by the effect of both Ga and Ag present on the surface, especially for Pseudomonas aeruginosa, one of the main pathogens involved in orthopedic implant failures. SaOS-2 cells adhere and proliferate on the Ga/Ag-doped Ti surfaces, and the presence of gallium favors cell differentiation. The dual effect of both metallic agents doping the titanium surface provides bioactivity while protecting the biomaterial from the most frequent pathogens in implantology.


Assuntos
Gálio , Titânio , Titânio/farmacologia , Titânio/química , Prata/farmacologia , Prata/química , Osseointegração , Porosidade , Gálio/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Materiais Revestidos Biocompatíveis/química , Antibacterianos/farmacologia , Antibacterianos/química , Propriedades de Superfície
4.
Biomater Adv ; 146: 213311, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36709627

RESUMO

The rapid integration in the bone tissue and the prevention of bacterial infection are key for the success of the implant. In this regard, a silver (Ag)-doped thermochemical treatment that generate an Ag-doped calcium titanate layer on titanium (Ti) implants was previously developed by our group to improve the bone-bonding ability and provide antibacterial activity. In the present study, the biological and antibacterial potential of this coating has been further studied. In order to prove that the Ag-doped layer has an antibacterial effect with no detrimental effect on the bone cells, the behavior of osteoblast-like cells in terms of cell adhesion, morphology, proliferation and differentiation was evaluated, and the biofilm inhibition capacity was assessed. Moreover, the competition by the surface between cell and bacteria was carried out in two different co-culture methods. Finally, the treatment was applied to porous Ti implants to study in vivo osteointegration. The results show that the incorporation of Ag inhibits the biofilm formation and has no effect on the performance of osteoblast-like cells. Therefore, it can be concluded that the Ag-doped surface is capable of preventing bone bacterial infection and providing suitable osseointegration.


Assuntos
Prata , Titânio , Prata/farmacologia , Titânio/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Materiais Revestidos Biocompatíveis/metabolismo , Antibacterianos/farmacologia , Osteoblastos/metabolismo , Bactérias
5.
Int J Mol Sci ; 23(3)2022 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-35163682

RESUMO

A lack of primary stability and osteointegration in metallic implants may result in implant loosening and failure. Adding porosity to metallic implants reduces the stress shielding effect and improves implant performance, allowing the surrounding bone tissue to grow into the scaffold. However, a bioactive surface is needed to stimulate implant osteointegration and improve mechanical stability. In this study, porous titanium implants were produced via powder sintering to create different porous diameters and open interconnectivity. Two strategies were used to generate a bioactive surface on the metallic foams: (1) an inorganic alkali thermochemical treatment, (2) grafting a cell adhesive tripeptide (RGD). RGD peptides exhibit an affinity for integrins expressed by osteoblasts, and have been reported to improve osteoblast adhesion, whereas the thermochemical treatment is known to improve titanium implant osseointegration upon implantation. Bioactivated scaffolds and control samples were implanted into the tibiae of rabbits to analyze the effect of these two strategies in vivo regarding bone tissue regeneration through interconnected porosity. Histomorphometric evaluation was performed at 4 and 12 weeks after implantation. Bone-to-implant contact (BIC) and bone in-growth and on-growth were evaluated in different regions of interest (ROIs) inside and outside the implant. The results of this study show that after a long-term postoperative period, the RGD-coated samples presented higher quantification values of quantified newly formed bone tissue in the implant's outer area. However, the total analyzed bone in-growth was observed to be slightly greater in the scaffolds treated with alkali thermochemical treatment. These results suggest that both strategies contribute to enhancing porous metallic implant stability and osteointegration, and a combination of both strategies might be worth pursuing.


Assuntos
Álcalis/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Metalurgia , Oligopeptídeos/farmacologia , Osseointegração , Temperatura , Alicerces Teciduais/química , Titânio/farmacologia , Animais , Feminino , Implantes Experimentais , Osseointegração/efeitos dos fármacos , Osteogênese/efeitos dos fármacos , Porosidade , Pós , Coelhos
6.
Materials (Basel) ; 15(2)2022 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-35057263

RESUMO

The passivation of titanium dental implants is performed in order to clean the surface and obtain a thin layer of protective oxide (TiO2) on the surface of the material in order to improve its behavior against corrosion and prevent the release of ions into the physiological environment. The most common chemical agent for the passivation process is hydrochloric acid (HCl), and in this work we intend to determine the capacity of citric acid as a passivating and bactericidal agent. Discs of commercially pure titanium (c.p.Ti) grade 4 were used with different treatments: control (Ctr), passivated by HCl, passivated by citric acid at 20% at different immersion times (20, 30, and 40 min) and a higher concentration of citric acid (40%) for 20 min. Physical-chemical characterization of all of the treated surfaces has been carried out by scanning electronic microscopy (SEM), confocal microscopy, and the 'Sessile Drop' technique in order to obtain information about different parameters (topography, elemental composition, roughness, wettability, and surface energy) that are relevant to understand the biological response of the material. In order to evaluate the corrosion behavior of the different treatments under physiological conditions, open circuit potential and potentiodynamic tests have been carried out. Additionally, ion release tests were realized by means of ICP-MS. The antibacterial behavior has been evaluated by performing bacterial adhesion tests, in which two strains have been used: Pseudomonas aeruginosa (Gram-) and Streptococcus sanguinis (Gram+). After the adhesion test, a bacterial viability study has been carried out ('Life and Death') and the number of colony-forming units has been calculated with SEM images. The results obtained show that the passivation with citric acid improves the hydrophilic character, corrosion resistance, and presents a bactericide character in comparison with the HCl treatment. The increasing of citric acid concentration improves the bactericide effect but decreases the corrosion resistance parameters. Ion release levels at high citric acid concentrations increase very significantly. The effect of the immersion times studied do not present an effect on the properties.

7.
Materials (Basel) ; 14(11)2021 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-34072082

RESUMO

The surface modification by the formation of apatitic compounds, such as hydroxyapatite, improves biological fixation implants at an early stage after implantation. The structure, which is identical to mineral content of human bone, has the potential to be osteoinductive and/or osteoconductive materials. These calcium phosphates provoke the action of the cell signals that interact with the surface after implantation in order to quickly regenerate bone in contact with dental implants with mineral coating. A new generation of calcium phosphate coatings applied on the titanium surfaces of dental implants using laser, plasma-sprayed, laser-ablation, or electrochemical deposition processes produces that response. However, these modifications produce failures and bad responses in long-term behavior. Calcium phosphates films result in heterogeneous degradation due to the lack of crystallinity of the phosphates with a fast dissolution; conversely, the film presents cracks, which produce fractures in the coating. New thermochemical treatments have been developed to obtain biomimetic surfaces with calcium phosphate compounds that overcome the aforementioned problems. Among them, the chemical modification using biomineralization treatments has been extended to other materials, including composites, bioceramics, biopolymers, peptides, organic molecules, and other metallic materials, showing the potential for growing a calcium phosphate layer under biomimetic conditions.

8.
Colloids Surf B Biointerfaces ; 182: 110317, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31323450

RESUMO

Biomaterial-associated infections (BAI) are the major cause of failure of indwelling medical devices. The risk of BAI can end dramatically in the surgical removal of the affected device. Therefore, a major effort must be undertaken to guarantee the permanence of the implant. In this regard, we have developed antimicrobial coatings for tantalum (Ta) implants, using polyhydroxyalkanoates (PHAs) as matrices for carrying an active principle. The dip-coating technique was successfully used for covering solid Ta discs. An original PHA emulsion flow process was developed for the coating of porous Ta structures, specially for the inner surfaces. The complete characterization of the biopolymer coatings, their antibacterial properties, toxicity and biointegration were analyzed. Thus, non-toxic, well-biointegrated homogeneous biopolymer coatings were attained, which showed antibacterial properties. By using biodegradable PHAs, the resulting drug delivery system assured the protection of Ta against bacterial infections for a period of time.


Assuntos
Anti-Infecciosos/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Poli-Hidroxialcanoatos/farmacologia , Próteses e Implantes , Tantálio/química , Anti-Infecciosos/química , Adesão Celular/efeitos dos fármacos , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/química , Escherichia coli/efeitos dos fármacos , Escherichia coli/crescimento & desenvolvimento , Humanos , Testes de Sensibilidade Microbiana , Osteoblastos/citologia , Osteoblastos/efeitos dos fármacos , Poli-Hidroxialcanoatos/química , Porosidade , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/crescimento & desenvolvimento
9.
J Mater Sci Mater Med ; 29(8): 131, 2018 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-30088100

RESUMO

The aim is to investigate the premature catastrophic fracture produced for different periods during clinical endodontic treatment of two brands of NiTi endodontic rotary instruments. 3 samples as-received, 6 samples used with patients for 2 and 7 h and 5 samples fractured were studied for each brand of endodontic NiTi rotary instruments. Transformation temperatures (Ms, Mf, As and Af) and enthalpies of transformation were determined by calorimetry. Critical stresses until fracture (σß→SIM, σSIM→ß) were obtained using an electromechanical testing machine. The samples were also visualized by Scanning Electron Microscopy. Calorimetric studies have shown an increase of the Ms and As transformation temperatures with time of use as well as a decrease of their stress transformations. Moreover, reverse transformation enthalpies decreased along the time. The enthalpies of transformation decreased because martensitic plates were anchored, which prevented their transformation to austenite; thus losing its superelastic effect. The stabilisation of the martensitic plates induced the collapse of the structure and so the main cause for the fracture. The heat treatment proposed has been increased the life in service of NiTi superelastic endodontic instruments recovering theirs superelastic effect.


Assuntos
Ligas/química , Instrumentos Odontológicos , Materiais Biocompatíveis , Humanos , Teste de Materiais , Temperatura , Termodinâmica
10.
Materials (Basel) ; 9(6)2016 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-28773526

RESUMO

A bioactive layer, free of nickel, has been performed for its greater acceptability and reliability in clinical applications for NiTi shape memory alloys. In the first step, a safe barrier against Ni release has been produced on the surface by means of a thicker rutile/anastase protective layer free of nickel. In the second step, a sodium alkaline titanate hydrogel, which has the ability to induce apatite formation, has been performed from oxidized surface. An improvement of host tissue-implant integration has been achieved in terms of Ni ions release and the bioactivity of the treated NiTi alloys has been corroborated with both in vitro and in vivo studies. The transformation temperatures (As, Af, Ms, and Mf), as well as the critical stresses (σß⇔M), have been slightly changed due to this surface modification. Consequently, this fact must be taken into account in order to design new surface modification on NiTi implants.

11.
J Mater Sci Mater Med ; 26(2): 109, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25665847

RESUMO

The use of tantalum as biomaterial for orthopedic applications is gaining considerable attention in the clinical practice because it presents an excellent chemical stability, body fluid resistance, biocompatibility, and it is more osteoconductive than titanium or cobalt-chromium alloys. Nonetheless, metallic biomaterials are commonly bioinert and may not provide fast and long-lasting interactions with surrounding tissues. The use of short cell adhesive peptides derived from the extracellular matrix has shown to improve cell adhesion and accelerate the implant's biointegration in vivo. However, this strategy has been rarely applied to tantalum materials. In this work, we have studied two immobilization strategies (physical adsorption and covalent binding via silanization) to functionalize tantalum surfaces with a cell adhesive RGD peptide. Surfaces were used untreated or activated with either HNO3 or UV/ozone treatments. The process of biofunctionalization was characterized by means of physicochemical and biological methods. Physisorption of the RGD peptide on control and HNO3-treated tantalum surfaces significantly enhanced the attachment and spreading of osteoblast-like cells; however, no effect on cell adhesion was observed in ozone-treated samples. This effect was attributed to the inefficient binding of the peptide on these highly hydrophilic surfaces, as evidenced by contact angle measurements and X-ray photoelectron spectroscopy. In contrast, activation of tantalum with UV/ozone proved to be the most efficient method to support silanization and subsequent peptide attachment, displaying the highest values of cell adhesion. This study demonstrates that both physical adsorption and silanization are feasible methods to immobilize peptides onto tantalum-based materials, providing them with superior bioactivity.


Assuntos
Materiais Revestidos Biocompatíveis/síntese química , Oligopeptídeos/química , Osseointegração/fisiologia , Osteoblastos/citologia , Osteoblastos/fisiologia , Tantálio/química , Adsorção , Adesão Celular/efeitos dos fármacos , Adesão Celular/fisiologia , Linhagem Celular , Materiais Revestidos Biocompatíveis/efeitos da radiação , Humanos , Teste de Materiais , Oligopeptídeos/efeitos dos fármacos , Oligopeptídeos/efeitos da radiação , Ozônio/farmacologia , Ligação Proteica , Propriedades de Superfície/efeitos dos fármacos , Propriedades de Superfície/efeitos da radiação , Tantálio/efeitos da radiação , Raios Ultravioleta
12.
Artigo em Inglês | MEDLINE | ID: mdl-25063084

RESUMO

A new thermoplastic polymer for orthodontic applications was obtained and extruded into wires with round and rectangular cross sections. We evaluated the potential of new aesthetic archwire: tensile, three point bending, friction and stress relaxation behaviour, and formability characteristics were assessed. Stresses delivered were generally slightly lower than typical beta-titanium and nickel-titanium archwires. The polymer wire has good instantaneous mechanical properties; tensile stress decayed about 2% over 2h depending on the initial stress relaxation for up to 120h. High formability allowed shape bending similar to that associated with stainless steel wires. The friction coefficients were lower than the metallic conventional archwires improving the slipping with the brackets. This new polymer could be a good candidate for aesthetic orthodontic archwires.


Assuntos
Materiais Biocompatíveis/química , Fios Ortodônticos , Polímeros/química , Temperatura , Fricção , Teste de Materiais , Estresse Mecânico
13.
J Biomed Mater Res A ; 101(3): 819-26, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22962002

RESUMO

ß-type titanium alloys with low Young's modulus are desirable to reduce stress shielding effect and enhance bone remodeling for implants used to substitute failed hard tissue. For biomaterials application, the surface bioactivity is necessary to achieve optimal osseointegration. In the previous work, the low elastic modulus (43 GPa) Ti-25Nb-16Hf (wt %) alloy was mechanically and microstructurally characterized. In the present work, the biological behavior of Ti-25Nb-16Hf was studied. The biological response was improved by surface modification. The metal surface was modified by oxygen plasma and subsequently silanized with 3-chloropropyl(triethoxy)silane for covalent immobilization of the elastin-like polymer. The elastin-like polymer employed exhibits RGD bioactive motives inspired to the extracellular matrix in order to improve cell adhesion and spreading. Upon modification, the achieved surface presented different physical and chemical properties, such as surface energy and chemical composition. Subsequently, osteoblast adhesion, cell numbers, and differentiation studies were performed to correlate surface properties and cell response. The general tendency was that the higher surface energy the higher cell adhesion. Furthermore, cell culture and immunofluorescence microscopy images demonstrated that RGD-modified surfaces improved adhesion and spreading of the osteoblast cell type.


Assuntos
Ligas/química , Materiais Revestidos Biocompatíveis/química , Módulo de Elasticidade , Elastina/química , Osteoblastos/metabolismo , Polímeros/química , Adesão Celular , Linhagem Celular , Humanos , Teste de Materiais , Oligopeptídeos/química , Osteoblastos/citologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...